The primary reformer is the single largest energy consumer in a syngas plant, and its performance hinges on keeping tube wall temperature (TWT) as close as possible to — but never above — the tube’s mechanical design temperature.
The most common measurement method used across the industry systematically overstates that temperature. Understanding why, and what to do about it, has direct production consequences.
Why TWT Accuracy Matters
The stakes are concrete. Operating just 20°C above design temperature cuts tube lifetime in half, while suboptimal TWT profiles at the low end cause high methane slip and reduced production.
The most widely used measurement technique, optical infrared (IR) pyrometry, infers temperature from Planck’s law of blackbody radiation. Two effects distort the raw reading: tube wall emissivity is never actually 1, the value for a perfect blackbody, and background radiation from refractory walls, other tubes and flames also reaches the pyrometer.
The result is that pyrometer readings are most often 20–100°C too high, forcing operators to run a higher-than-necessary safety margin below design temperature — margin that translates directly into lost production capacity.
1.0 μm versus 3.9 μm Pyrometers
Two pyrometer wavelengths dominate industry use, 1.0 μm and 3.9 μm, with standard assumed tube-wall emissivities of 0.85 and 0.82 respectively.
The 3.9-μm instrument, introduced in the 1990s, is less sensitive to the two dominant sources of error when furnace background temperature exceeds tube temperature, which is the typical reformer condition. A 20°C swing in furnace wall temperature moves the measured TWT by only 5°C for the 3.9-μm instrument, against 16°C for the 1.0-μm instrument under otherwise identical conditions.
Lower sensitivity to error is not the same as higher accuracy. The 3.9-μm pyrometer consistently reads higher than both thermocouples and reformer-simulation predictions, while the 1.0-μm pyrometer, properly used, agreed with both.
The practical guidance follows directly. Without thorough operator training, use the 3.9-μm instrument, since its higher, more conservative readings keep any resulting operating adjustments safely within design limits. With training, the 1.0-μm instrument can achieve genuinely better accuracy despite its greater sensitivity to measurement error.
Gold Cup Reference Measurements
The most rigorous available reference method is gold cup pyrometry, which surrounds the target with a gold-plated hemisphere that effectively behaves as a true blackbody. This eliminates both the emissivity and background-radiation error sources, at the cost of a heavy, cumbersome instrument with limited furnace-insertion reach.
A 2015 comparison study across two side-fired reformers found that both standard pyrometer types, even after correction using the standard assumed emissivities, typically read higher than the gold cup reference.
That means the industry-standard emissivity assumptions of 0.85 and 0.82 are themselves generally too high relative to actual tube conditions — a pattern independently corroborated by a joint research project with the Technical University of Denmark for the 1.0-μm case specifically.
Managing the Measurement Problem in Practice
Two practical responses address these measurement challenges. The first is a structured four-level Steam Reformer Assessment and Optimization service, running from a Level 1 spot check through to Level 4’s full gold-cup emissivity determination.
The second is the Topsoe Furnace Manager (TFM), a permanent image-acquisition system providing continuous, remote real-time TWT and flame monitoring without requiring peephole doors to be opened.
Beyond the direct temperature-management benefit, the TFM improves personnel safety, since no direct furnace-box interaction is required. Concrete operational outcomes include sustained safe operation with older end-of-life catalyst tubes, continued operation with a small furnace-box leak managed for over two years, and one case where catalyst-tube creep measurements stayed under 1% after 45,000 operating hours.
Economic benefits are of the order of a few hundred thousand USD per year each in fuel savings and personnel-productivity gains.
| SOURCE & ATTRIBUTION Source: P. B. Jensen, S. M. King, K. B. Carlsen, “Operating At Peak Performance With Topsoe Reformer Management,” Haldor Topsoe A/S, Nitrogen + Syngas 2016 International Conference, Berlin, 29 February – 3 March 2016. |