Search

Ammonia storage

For over 100 years, ammonia has been stored as a liquid since the onset of industrial-scale production. Initially, pressurized systems like bullets and Horton spheres were used for storage, with spheres typically accommodating up to 2,000 tonnes. Nowadays, atmospheric ammonia storage tanks are common and can store up to 50,000 tonnes at plant sites and distribution terminals.

Fertilizer Industrial Services assumed a critical role as the Owner Engineer consultants in the development of a large-capacity tanks for high-profile fertilizer industrial facility. Our scope of work encompassed comprehensive oversight of the engineering design review, performing in-depth technical reviews, and ensuring adherence to stringent industry codes such as API 620 and ASME standards. Leveraging our expertise in ammonia handling and storage technologies, we collaborated closely with the project stakeholders to validate design specifications, materials selection, and construction methodologies. Additionally, Fertilizer Industrial Services provided ongoing technical support during construction, commissioning and start-up, ensuring that the NH3 tanks achieved optimal operational safety, reliability, and compliance with environmental and process safety regulations, while supporting the facility’s long-term operational needs.

Low-pressure ammonia storage has gained widespread acceptance for two key reasons: it requires significantly lower capital investment per unit volume and offers greater safety compared to sphere storage, which operates at pressures higher than atmospheric. With the advent of large-scale ammonia production, storing ammonia at atmospheric pressure and -33°C has become the norm.

Types of ammonia tanks

The main types of atmospheric tanks operating at -33°C are:

  • Single-wall steel tanks with external insulation (Figure 1). Some of these tanks are surrounded by concrete bunds to contain the entire volume of the tank’s contents.
  • Double-wall tanks or double containment tanks, which consist of steel tanks with perlite insulation between the walls (Figure 2).

There are also two variations of double-wall, double-integrity (DWDI) tanks: those with insulation in the annular space (Figure 3) and those with insulation on the outer tank (Figure 4).

Ammonia storage tank type 1: Single wall tank
Fig. 1 Single wall tank
Ammonia storage tank type 2: Double wall (double containment) tank
Fig 2: Double wall (double containment) tank
Ammonia storage tank type 3: Double wall, double integrity tank (full containment) with insulation in annular space
Fig 3: Double wall, double integrity tank (full containment) with insulation in annular space
Ammonia storage tank type 4 Double wall, double integrity tank (full containment) with insulation on outer tank
Fig. 4 Double wall, double integrity tank (full containment) with insulation on outer tank

The DWDI tank with insulation on the outer tank can continue operating longer in the event of an inner tank failure, while the tank with insulation in the annular space must be decommissioned if the inner tank fails, as its outer tank lacks insulation. DWDI tanks with insulation in the annular space are more cost-effective than those with insulation on the outer tank. Both types of double-wall tanks are designed to fully contain the contents within the inner tank and are constructed from low-temperature carbon steel.

In the figures, the different tank designs are shown supported by piles, which are generally the standard for newly designed tanks. However, in the past, single-wall tanks were often placed directly on compacted soil or sand foundations, which required under-tank heating coils (foundation heaters) to prevent frost formation and potential ground heaving.

icon of an engineer remembering what he learnedAlthough single-wall tanks were commonly built at many sites historically, current practices, supported by quantitative risk assessment (QRA), recommend using DWDI tanks for bulk storage to achieve an As Low As Reasonably Practicable (ALARP) risk level. Data from HSE UK, the Purple Book / SGS 3 by VROM Netherlands, and Belgium’s Failure Rates Handbook show that the failure rate for DWDI full containment tanks is nearly one-hundredth of that for single-wall tanks. Standards for atmospheric ammonia tanks are still evolving, with risk assessment previously excluded from many standards. API 625, which references API 620, advises that tank purchasers perform a risk assessment to determine the appropriate tank configuration.

The design, installation, and operation of tanks should follow best practices and operating procedures, utilizing tools like HAZID, HAZOP, and bow-tie analysis to evaluate risks. Design elements and ancillary equipment for each storage tank may vary, but systematic attention should be given throughout the tank’s lifespan to components such as relief valves, nozzles, drainage systems, insulation for the roof, walls, and bottom, foundation and pile inspections (including elevation surveys), tank integrity checks (especially weld joints), acoustic emission testing (AET), piping inspections, and fitness-for-service assessments.

Ammonia storage tank design and safety considerations

The following design recommendations are essential for ensuring high-integrity ammonia tanks:

  • The storage tank should be of a double-wall, double-integrity type with insulation on the outer wall and designed for an internal pressure of 14 kPag.
  • The tank must be designed, fabricated, erected, and tested according to API 620, Appendix R. The updated API 625 code, published in 2010, outlines various tank systems (single, double, and full containment) and references the 2012 edition of API 620 for steel tank construction and the 2010 edition of ACI 376 for concrete tank construction.
  • It is recommended that the tank be installed on an elevated, piled concrete slab foundation to prevent the ground from freezing beneath the tank, thus avoiding potential foundation or tank damage due to frost heave. The concrete slab should be approximately two meters above the surrounding ground level.
  • The foundation and tank must be designed to handle the full hydrostatic testing of the tank, with hydro-tests performed on both the inner and outer tanks. The design should also account for thermal expansion to reduce bending stress on the tank shell.
  • In seismic regions, a detailed seismic analysis of the tank and associated piping must be conducted.
  • The design must comply with national standards for cyclonic wind and earthquake conditions.
  • It should also be suited for installation in a marine environment.
  • Drainage systems must be included for both the inner and outer tanks.

Fertilizer Industrial Services was engaged as an expert Engineer Consultant to develop comprehensive procedures for the De-Commissioning and Commissioning, Start-up, and Operation of several NH3 storage tanks for a US client. Our role included drafting detailed protocols that addressed critical stages of the de-commissioning and re-commissioning process, as listed below. For the start-up phase, we provided customized operational guidelines, ensuring that the system was brought online in compliance with industry standards, such as API 620 and OSHA regulations, while maintaining optimal safety and efficiency.

Fertilizer Industrial Services has the expertise to create robust operational procedures to support long-term maintenance, monitoring, and emergency response plans, enabling a facility to operate the ammonia storage tanks with maximum reliability and safety throughout its lifecycle.

COMMISSIONING

  • Purge the tank with nitrogen until the measured oxygen content in the discharge gas is less than 4% (vol.).
  • Purge the tank with ammonia vapor until the oxygen content drops below 0.5% (vol.).
  • Cool the tank by injecting liquid ammonia at a rate of less than 2°C per hour, ideally using a spray system, to reach the lowest possible temperature.
  • Monitor the temperatures inside the tank away from the gas inlet.
  • Take samples of the liquid ammonia from the tank and analyze them for water and oxygen content.
  • Maintain a minimum moisture level of 2,000 ppm during tank operation to prevent stress corrosion cracking (SCC).

DECOMMISSIONING

  • Reduce the tank’s liquid ammonia to the absolute minimum level.
  • Evaporate the remaining ammonia by ensuring uniform and gradual heating, not exceeding 2°C per hour.
  • Purge the tank with warm ammonia until all liquid ammonia has been fully removed.
  • Purge the ammonia gas from the tank using nitrogen instead of air to avoid creating an explosive mixture.
  • Direct ammonia vapor-containing streams to a flare to prevent environmental contamination.
  • Purge the nitrogen atmosphere with air until the oxygen content exceeds 19%. If ammonia is still detected in the gas phase, use breathing apparatus when entering the tank.
  • Additional cleaning methods may be required to remove residual oil remnants, along with enhanced safety measures and specialized equipment for personnel.

INDUSTRY STANDARDS

Here are some of the key industry standards applicable to ammonia storage tanks. These standards ensure that ammonia storage tanks are designed and operated safely to minimize risks associated with ammonia’s hazardous properties.:

  • API 620 – Design and Construction of Large, Welded, Low-Pressure Storage Tanks
  • API 625 – Tank Systems for Refrigerated Liquefied Gas Storage
  • BS 7777 – Flat-Bottomed, Vertical, Cylindrical Storage Tanks for Low-Temperature Service
  • EN 14620 – Design and Manufacture of Transportable Tanks for the Carriage of Dangerous Goods
  • ASME Boiler and Pressure Vessel Code – Rules for Construction of Power Boilers, Heating Boilers, Pressure Vessels, Transport Tanks
  • CGA G-2.1 – Requirements for the Storage and Handling of Anhydrous Ammonia
  • OSHA 29 CFR 1910.111 – Storage and Handling of Anhydrous Ammonia